000 -LEADER |
fixed length control field |
02984nam a22004455i 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20140310143359.0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
cr nn 008mamaa |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
110216s2011 ne | s |||| 0|eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
International Standard Book Number |
9789400706866 |
|
978-94-007-0686-6 |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER |
Classification number |
621.3815 |
Edition number |
23 |
264 #1 - |
-- |
Dordrecht : |
-- |
Springer Netherlands : |
-- |
Imprint: Springer, |
-- |
2011. |
912 ## - |
-- |
ZDB-2-ENG |
100 1# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Colomer-Farrarons, Jordi. |
Relator term |
author. |
245 12 - IMMEDIATE SOURCE OF ACQUISITION NOTE |
Title |
A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices |
Medium |
[electronic resource] : |
Remainder of title |
Three-Electrodes Amperometric Biosensor Approach / |
Statement of responsibility, etc |
by Jordi Colomer-Farrarons, Pere Lluís Miribel-Català. |
250 ## - EDITION STATEMENT |
Edition statement |
1. |
300 ## - PHYSICAL DESCRIPTION |
Extent |
XI, 200p. 145 illus., 25 illus. in color. |
Other physical details |
online resource. |
505 0# - FORMATTED CONTENTS NOTE |
Formatted contents note |
Preface / Abstract. Abbreviations -- 1 Introduction -- 2 Energy Harvesting (Multi Harvesting Power Chip) -- 3 Biomedical Integrated Instrumentation -- 4 CMOS Front-End Architecture for In-Vivo Biomedical Subcutaneous Detection Devices -- 5 Conclusions and Future Work -- 5.1 Conclusions -- 5.2 Future Work -- Appendix 1 -- Appendix.-. 2. Appendix 3. |
520 ## - SUMMARY, ETC. |
Summary, etc |
A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices presents the conception and prototype realization of a Self-Powered architecture for subcutaneous detector devices. The architecture is designed to work as a true/false (event detector) or threshold level alarm of some substances, ions, etc... that are detected through a three-electrodes amperometric BioSensor approach. The device is envisaged as a Low-Power subcutaneous implantable application powered by an inductive link, one emitter antenna at the external side of the skin and the receiver antenna under the skin. The sensor is controlled with a Potentiostat circuit and then, a post-processing unit detects the desired levels and activates the transmission via a backscattering method by the inductive link. All the instrumentation, except the power module, is implemented in the so called BioChip. Following the idea of the powering link to harvest energy of the magnetic induced link at the implanted device, a Multi-Harvesting Power Chip (MHPC) has been also designed. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name as entry element |
Physics. |
|
Topical term or geographic name as entry element |
Systems engineering. |
|
Topical term or geographic name as entry element |
Biomedical engineering. |
|
Topical term or geographic name as entry element |
Physics. |
|
Topical term or geographic name as entry element |
Electronic Circuits and Devices. |
|
Topical term or geographic name as entry element |
Biomedical Engineering. |
|
Topical term or geographic name as entry element |
Circuits and Systems. |
|
Topical term or geographic name as entry element |
Solid State Physics. |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Miribel-Català, Pere Lluís. |
Relator term |
author. |
710 2# - ADDED ENTRY--CORPORATE NAME |
Corporate name or jurisdiction name as entry element |
SpringerLink (Online service) |
773 0# - HOST ITEM ENTRY |
Title |
Springer eBooks |
776 08 - ADDITIONAL PHYSICAL FORM ENTRY |
Display text |
Printed edition: |
International Standard Book Number |
9789400706859 |
856 40 - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
http://dx.doi.org/10.1007/978-94-007-0686-6 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
|
Item type |
E-Book |