//]]>

A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices (Record no. 12576)

000 -LEADER
fixed length control field 02984nam a22004455i 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20140310143359.0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field cr nn 008mamaa
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 110216s2011 ne | s |||| 0|eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9789400706866
978-94-007-0686-6
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 621.3815
Edition number 23
264 #1 -
-- Dordrecht :
-- Springer Netherlands :
-- Imprint: Springer,
-- 2011.
912 ## -
-- ZDB-2-ENG
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Colomer-Farrarons, Jordi.
Relator term author.
245 12 - IMMEDIATE SOURCE OF ACQUISITION NOTE
Title A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices
Medium [electronic resource] :
Remainder of title Three-Electrodes Amperometric Biosensor Approach /
Statement of responsibility, etc by Jordi Colomer-Farrarons, Pere Lluís Miribel-Català.
250 ## - EDITION STATEMENT
Edition statement 1.
300 ## - PHYSICAL DESCRIPTION
Extent XI, 200p. 145 illus., 25 illus. in color.
Other physical details online resource.
505 0# - FORMATTED CONTENTS NOTE
Formatted contents note Preface / Abstract. Abbreviations -- 1 Introduction -- 2 Energy Harvesting (Multi Harvesting Power Chip) -- 3 Biomedical Integrated Instrumentation -- 4 CMOS Front-End Architecture for In-Vivo Biomedical Subcutaneous Detection Devices -- 5 Conclusions and Future Work -- 5.1 Conclusions -- 5.2 Future Work -- Appendix 1 -- Appendix.-. 2. Appendix 3.
520 ## - SUMMARY, ETC.
Summary, etc A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices presents the conception and prototype realization of a Self-Powered architecture for subcutaneous detector devices. The architecture is designed to work as a true/false (event detector) or threshold level alarm of some substances, ions, etc... that are detected through a three-electrodes amperometric BioSensor approach. The device is envisaged as a Low-Power subcutaneous implantable application powered by an inductive link, one emitter antenna at the external side of the skin and the receiver antenna under the skin. The sensor is controlled with a Potentiostat circuit and then, a post-processing unit detects the desired levels and activates the transmission via a backscattering method by the inductive link. All the instrumentation, except the power module, is implemented in the so called BioChip. Following the idea of the powering link to harvest energy of the magnetic induced link at the implanted device, a Multi-Harvesting Power Chip (MHPC) has been also designed.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Physics.
Topical term or geographic name as entry element Systems engineering.
Topical term or geographic name as entry element Biomedical engineering.
Topical term or geographic name as entry element Physics.
Topical term or geographic name as entry element Electronic Circuits and Devices.
Topical term or geographic name as entry element Biomedical Engineering.
Topical term or geographic name as entry element Circuits and Systems.
Topical term or geographic name as entry element Solid State Physics.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Miribel-Català, Pere Lluís.
Relator term author.
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element SpringerLink (Online service)
773 0# - HOST ITEM ENTRY
Title Springer eBooks
776 08 - ADDITIONAL PHYSICAL FORM ENTRY
Display text Printed edition:
International Standard Book Number 9789400706859
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://dx.doi.org/10.1007/978-94-007-0686-6
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Item type E-Book
Copies
Price effective from Permanent location Date last seen Not for loan Date acquired Source of classification or shelving scheme Koha item type Damaged status Lost status Withdrawn status Current location Full call number
2014-04-03AUM Main Library2014-04-03 2014-04-03 E-Book   AUM Main Library621.3815

Languages: 
English |
العربية